Comparison of Optic Disc on Machine (OCT) Versus Manual Assessment on Slit Lamp

Authors

  • Dr. Vatsala Vats Associate Professor, Department of Ophthalmology, Shri Guru Ram Rai Institute of Medical and Health Sciences Dehradun, Uttarakhand
  • Dr. Priyanka Gupta Associate Professor, Department of Ophthalmology, Shri Guru Ram Rai Institute of Medical and Health Sciences Dehradun, Uttarakhand
  • Dr. Mohd. Ghainual Hasan Assistant Professor, Department of Ophthalmology, Shri Guru Ram Rai Institute of Medical and Health Sciences Dehradun, Uttarakhand
  • Dr. Ashish Kundu Junior Resident, Department of Ophthalmology, Shri Guru Ram Rai Institute of Medical and Health Sciences Dehradun, Uttarakhand
  • Dr. Shivani Raturi Junior Resident, Department of Ophthalmology, Shri Guru Ram Rai Institute of Medical and Health Sciences Dehradun, Uttarakhand

DOI:

https://doi.org/10.14738/bjhmr.102.14226

Keywords:

Optic disc, Glaucoma, OCT, Glaucoma Suspect

Abstract

Background and Objectives: OCT is an evolving tool of diagnosing various anatomical anomalies of eye specially for retinal parameters and also gaining a strong role in other structures like cornea, angle, optic disc. But its cost and incorporation of newer technology with time becomes a dilemma for its purchase. The subjective assessment of optic nerve head (ONH) with the help of 90 dioptre, or 78 dioptre lens on slit lamp, or direct ophthalmoscope are methods in common clinical practice in most ophthalmic settings. Such manual assessment forms the core of the strategic approach to diagnose optic disc variations. This study aimed to learn if objective tool like OCT could do away the subjective method.  Material and Method: All eyes underwent comprehensive ophthalmic evaluation including visual acuity, slit lamp biomicroscopy, tonometry, and OCT. The optic disc was assessed on slit lamp by 78 D as the morphology appeared close to natural dimensions. Disc size, NRR, C:D ratio noted on OCT were compared with the readings of manual method. Study Design: A cross sectional, hospital based, prospective study involving 200 eyes of 100 patients. Result: In our study, we found that the size was significantly more on OCT than manual assessment on slit lamp with 78 dioptre lens. Glaucoma Suspect eyes on slit lamp were found to have suspicious discs even on OCT in almost 90% eyes. Interpretation & Conclusion: Subjective assessment is mandatory for diagnostic purposes as it is vivid, and is easily available on account of low cost. OCT is additive of information of structures not visible to human eye directly. A proper combination of OCT and SLB brings specificity and clarity to both the patient and clinician.

References

Rebolleda G et al. OCT: New perspectives in neuro-ophthalmology. Saudi Journal of Ophthalmology. 2015; 29: 9–25.

Saini C, Shen Lucy Q. Monitoring Glaucoma Progression with OCT. Review of Ophthalmology. 2020; 5: 48-55.

Deleon-Ortega JE, Arthur SN, McGwin G Jr, et al. Discrimination between glaucomatous and non glaucomatous eyes using

quantitative imaging devices and subjective optic nerve head assessment. Invest Ophthalmol Vis Sci. 2006; 47: 3374-3380.

Sehi M, Greenfield DS. Assessment of the retinal nerve fiber layer using optic coherence tomography and scan¬ning laser

polarimetry in progressive glaucomatous optic neuropathy. Am J Ophthalmol. 2006; 142: 1056-1059.

Chauhan BC, Burgoyne CF. From clinical examination of the optic disc to clinical assessment of the optic nerve head: a paradigm

change. Am J Ophthalmol. 2013; 156: 218-227.

Mwanza J-C, Warren JL, Budenz DL, et al. Combining spectral-domain optical coherence tomography structural parameters for the

diagnosis of glaucoma with early visual field loss. Invest Ophthalmol Vis Sci. 2013; 54: 8393-8400.

Chauhan BC, O’Leary N, Al Mobarak FA, et al. Enhanced detection of open-angle glaucoma with an anatomically accurate optical

coherence tomography-derived neuroretinal rim parameter. Ophthalmology. 2013; 120: 535-543.

Reis ASC, Sharpe GP, Yang H, et al. Optic disc margin anatomy in patients with glaucoma and normal controls with spectral-domain

optical coherence tomography. Ophthalmology. 2012; 119: 738-747.

Vessani RM, Moritz R, Batis L, et al. Comparison of quantitative imaging devices and subjective optic nerve head assessment by

general ophthalmologists to differentiate normal from glaucomatous eyes. J Glaucoma. 2009;18(3): 253-61.

Michelessi M, Lucenteforte E, Oddone F, et al. Optic nerve head and fibre layer imaging for diagnosing glaucoma. Cochrane Database

Syst Rev. 2015; 30: CD008803.

Banister K, Boachie C, Bourne R, et al. Can Automated Imaging for Optic Disc and Retinal Nerve Fiber Layer Analysis Aid in Glaucoma

detection? Ophthalmology.2016;123:930-8.

Downloads

Published

2023-03-23

How to Cite

Dr. Vatsala Vats, Dr. Priyanka Gupta, Dr. Mohd. Ghainual Hasan, Dr. Ashish Kundu, & Dr. Shivani Raturi. (2023). Comparison of Optic Disc on Machine (OCT) Versus Manual Assessment on Slit Lamp. British Journal of Healthcare and Medical Research, 10(2), 97–103. https://doi.org/10.14738/bjhmr.102.14226